品牌
生产厂家厂商性质
扬州市所在地
交联聚乙烯绝缘控制电缆XPLE insulated Control Cable
一、适用范围 Application
本产品用于额定电压450/750V及以下控制、监控回路及保护线路等场合
Applicable to the control system,control loop and protectioncricuit with the rated voltage 450/750V(or lower).
二、执行标准
GB/T9330.3-2008
lmplementation ofstandards
GB/T9330.3-2008
三、使用特性
1.导体**工作温度90C。
2.安装敷设时环境温度不低于0C。
安装敷设时最小弯曲半径:无铠装6 X电缆外径,有屏蔽层软电缆36X电缆外径,有铠装或铜带屏蔽12X电缆外径
Using characteristics
1、The max working temperature of conductor(of a cablelis 90℃。
2、The ambient temperature for laying is not lower than 0℃。
3、The least allowed bending radius: steel tape-armoredcable is 6 times the outer diameter of the cable : 6 timesthe outer diameter of the cable(the screen soft cable):steel tape-armored or Cu tape armored shield calble is12 times the outer diameter of the cable
四、型号、名称 TypeandDenomination
型号 Type | 产品名称 Denomination |
KYJV,KYJY | 交联聚乙烯绝缘聚氯乙烯(聚烯烃)护套控制电缆 Cross-linked polyethylene insulated PVC sheathed control cable (polyolefin) |
KYJVP,KYJYP | 交联聚乙烯绝缘编织屏蔽聚氯乙烯(聚烯烃)护套控制电缆 Cross-linked polyethylene insulation weaving to PVC sheathed control cable (polyolefin) |
KYJVP2,KYJYP2 | 交联聚乙烯绝缘铜带屏蔽聚氯乙烯(聚烯)护套控制电缆 Cross-inked polyethylene insulated copper tape screened PVC sheathed control cable (polyolefin) |
KYJVP3.KYJYP3 | 交联聚乙烯绝缘铝塑复合带屏蔽聚氯乙烯(聚烯烃)护套控制电缆 Cross-linked polyethylene insulation composite tape screened PVC sheathed control cable (polyolefin) |
KYJV22,KYJY23 | 交联聚乙烯绝缘钢带铠装聚氯乙烯(聚烯烃)护套控制电缆 Cross-linked polyethylene insulating tape armored PVC sheathed control cable (polyolefin) |
KYJVP2-22,KYJYP2-23 | 交联聚乙烯绝缘铜带屏蔽钢带铠装聚氯乙烯(聚烯烃)护套控制电缆 Cross-linked polyethylene insulated copper tape BingBiGang tape armored PVC sheathed control cable(polyolefin) |
KYJV32,KYJY33 | 交联聚乙烯绝缘细钢丝铠装聚氯乙烯(聚烯烃)护套控制电缆 Cross-linked polyethylene insulation weaving fine steel wire armored PVC sheathed control cable(polyolefin) |
五、规格范围 Specification range
型号 Typ | 标称截面mm2 Nominal cross section area mm2 | ||||||
0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | |
芯数 Core NO. | |||||||
KYJV,KYJVP, KYJY,KYJYP | 2-61 | 2-14 | 2-10 | ||||
KYJVP2,KYJVP3, KYJYP2,KYJYP3 | 4-61 | 4-14 | 4-10 | ||||
KYJV22,KYJY23 | 7-61 | 4-61 | 4-14 | 4-10 | |||
KYJVP2-22,KYJYP2-23 | 7-61 | 4-61 | 4-14 | 4-10 | |||
KYJV32,KYJY33 | 19-61 | 7-61 | 4-14 | 4-10 |
六、主要技术参数 Technolgicalparameters
序号 No | 项目 Project | 单位 Unit | 指标 Index | 试验方法 Test method |
1 | 电缆结构及导体电阻 Cable structure and conductor resistance | 符合GB/T3956-2008标准(IEC60228:2004) Complies with the standard ofGB/T3956-2008(IEC60228:2004) | GB/T3048.4-2007 | |
2 | 绝缘线芯交流50Hz火花试验 Spark test(AC.Voltage 50Hz) | KV | 6 | GB/T3048.9-2007 |
3 | 工频5min电压试验 Frequency(5min)voltage test | KV | 3 | GB/T3048.8-2007 |
4 | 绝缘线芯电压试验 Insulation voltage test 0.6mm及以下≤0.6mm 0.6mm及以上=0.6mm | KV | 2 2.5 | GB/T3048.8-2007 |