金属屏蔽电力电缆Metal Shielding Power Cable
一、适用范围
本产品适用于额定电压0.6/1KV及以下的电力线路中作输送电能用。产品具有较强的电磁干扰、抗雷击及均衡电位,改善供电品质的特性,特别适宜计算机中心、航空航天监控中心,智能大楼等精密电子装置场所。
Scope ofapplication
It is used for power transmission on power lines of rated voltage0.6/1kV or lower.lt has strong resistant characters againstelectromagnetic interference, thunder strike and even electricpotential, improving power sup- ply quality. It is especially suitableto place with precision electronic devices such as computercenter, space & aviation supervision center and intellectualbuildings etc.
二、执行标准
企业标准
Executive standard
Enterprise standard
三、型号名称 Type and Description
型号 Type | 名称Description | |
铜 Cu | 铝AI | |
VVP VVP22 | VLVP VLVP22 | 铜、铝芯聚氯乙烯绝缘金属屏蔽(钢带铠装)聚氯乙烯护套电力电缆 Power cable with Cu/Al core, PVC insulation, metallic shielding(steel tape armor), PVC sheath |
YJVP YJVP22 | YJLVP YJLVP22 | 铜、铝芯交联聚乙烯绝缘金属屏蔽(钢带铠装)聚氯乙烯护套电力电缆 Power cable with Cu/Al core, XLPE insulation, metallic shielding(steel tape armor), PVC sheath |
注:
1、该产品可按用户的使用要求,设计成具有阻燃性能或耐火性能的产品。订货时只需在原型号前加“ZR-”表示阻燃型,加“NH-”表示耐火型;
2、电缆的金属屏蔽可按用户要求有两种形式:金属丝编织或金属带绕包;
3、如需软芯导体的电缆,应在原型号后加字母“R”。
Note:
1: We also produce cable with fame resistant performance or fire resistant performance accordina to the reauirement of customerPrefix “ZR-”should be added to the original type for flame retardant cable and “NH-" added for fire-resistant cable.
2: There are two kinds of metallic shielding. One is metallic wire braiding shielding. The other is metallic tape wrapped shielding.
3: Prefix“R”should be added to the original type for ordering cable with soft conductor;
四、规格 Specification
五、使用条件
1、导体**长期允许工作温度: 聚氯乙烯绝缘为70℃:交联聚乙烯绝缘为90℃。
2、电缆短路时(最长持续时间不超过5S),导体的**温度不超过:聚氯乙烯绝缘为160℃;交联聚乙烯绝缘为 250℃;
3、敷设时环境温度应不低于0℃。
4、电缆允许弯曲半径为:铠装电缆不小于电缆外径的20倍:非铠装电缆不小于电缆外径的15倍: 软芯导体电缆不小于电缆外径的10倍。
Working Condition
1: Max long-term working temperature allowed by conductor is70℃ for cable with PVC insulation, 90℃ for cable with XLPE insulation
2: Max temperature of conductor is no higher than160℃ for cablewith PVC insulation, 250℃ for cable with XLPE insulation duringshort circuit (The longest lasting time is no more than 5s).
3: Environment temperature for installation is not lower than 0℃
4: Bending radius allowed by cable is no less than 20 times that ofcable outer diameter for armored cable, 15 times that for inarmoredcable, 10times that for cable with soft conductor
六、电缆近似外径
VVP型、VLVP型电缆外径分别在VV型、VLV型电缆外径的基础上增加1~1.5mm²
YJVP型、YJLVP型电缆外径分别在YJV型YJLV型电缆外径的基础上增加1~1.5mm²
VV22P型、VLV22P型电缆外径分别在VV22型VLV22型电缆外径的基础上增加1.5mm²
YJV22P型YJLV22P型电缆外径分别在YJV22型YJLV22型电缆外径的基础上增加1.5mm²
Approximate Outer Diameter of Cable
Outer diameter value of VVP type and VLVP type cable shouldbe added by 1~1.5mm² on the basis of that of VV type and VLV typecable.
Outer diameter value of YJVP type and YJLVP type cable shouldbe added by 1~1.5mm²on the basis of that of YJV type and YJLVtype cable.
Outer diameter value of VV22P type and VLV22P type cableshould be added by1.5mm² on the basis of that of VV22 type andVLV22 type cable.
Outer diameter value of YJV22P type and YJLV22P type cableshould be added by 1.5mm²on the basis of that of YJV22 typeand YJLV22 type cable.
七、主要技术参数
1、20C时导体直流电阻
参见0.6/1kV聚氯乙烯绝缘及护套电力电缆
2、绝缘电阻
Main Technical Parameter
1: DC resistance of conductor at 20C
2:Insulated resistance
3、交流电压试验成品电缆经受交流50Hz、5min、3.5kV的电压试验绝缘应无击穿。
4、耐火型电缆的耐火特性应符合IEC60331或GB12666.6中的A类或B类耐火试验要求。
5、阻燃型电缆的阻燃性能应符合IEC60332或GB/T18380.3标准中规定的A、B或C三类中任一类别阻燃性能要求。
3: Finished cable should endure A.C voltage test of 3.5kV, AC50Hz for 5min without puncture.
4: Fire resistant performance of fire resistance cable should meettesting requirement of category A or B stipu- lated in IEC60331or GB12666.6 standard.
5: Flame retardant performance of Flame retardant cable shouldmeet testing requirement of category A or B or C stipulated inIEC60332 or GB/T18380.3standard.