J2100A Injection Transformer 1Hz~5MHz

J2100A Injection Transformer 1Hz~5MHz

参考价: 面议

具体成交价以合同协议为准
2023-08-30 15:52:51
167
产品属性
关闭
苏州全迪亚电子科技有限公司

苏州全迪亚电子科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

Low band corner frequency 达1Hz,可支持 功率因数控制器(PFC)之稳定性测试5MHz带宽足以量测大多数电源和稳压器超高频宽,可达23 Octave优异精确的低失真表现5Ω终端,对待测电路的影响降至最小包括衰减功能来确保小信号的测量正确性

详细介绍

Low band corner frequency 达1Hz,可支持 功率因数控制器(PFC)之稳定性测试
5MHz带宽足以量测大多数电源和稳压器
超高频宽,可达23 Octave
优异精确的低失真表现
5Ω终端,对待测电路的影响降至最小

包括衰减功能来确保小信号的测量正确性


产品说明


The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.

The usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.

The bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.

 

规格

Performance at -10dBm input level
Characteristic Rating
DCR  
Ratio 1:1
Termination Impedance 5 Ohms
Usable Bandwidth 1Hz - 5MHz (Terminated into 5 Ohms)
10Hz - 5MHz (Terminated into 50 Ohms)
Isolation Voltage 600V
Isolation Capacitance 390pF@1KHz
DC Current 10mA
Temperature Range 0 ~ 50°C
Maximum Altitude 6000 Ft

Note: The upper end of the bandwidth is heavily dependent on the interconnect between the Injector and the DUT.



上一篇:玩具触摸性测试方法 下一篇:塑料熔融指数测试指导书
热线电话 在线询价
提示

请选择您要拨打的电话: