The CT2 Current Probes are designed for permanent or semi-permanent in-circuit installation. Each probe consists of a curre
Bandwidth (typical) | 1.2 kHz to 200 MHz | |
Rise Time | 500 ps | |
Sensitivity (into 50 Ω) | 1 mV/mA | |
Accuracy | ±3% | |
Magnetizing Inductance | 7 μH | |
Leakage Inductance | 1 nH | |
Insertion Impedance: | ||
at 10 MHz | 0.1 Ω | |
at 100 MHz | 0.5 Ω | |
at 1 GHz | | |
Max. Bare Wire Size | #16 wire | |
1.32 mm (0.052 in.) | ||
Max. Bare Wire Voltage: | ||
RMS | 175 VRMS CAT I | |
Peak | 1000 V*1 | |
DC | 175 V | |
Max. Peak Pulse Current | 36 A | |
Max. Continuous Current (RMS) | 2.5 A | |
Amp-second Product | 50 × 10-6 A*Sec | |
L/R Time Constant (droop) | >160 μs | |
Propagation Delay | 6.1 ns |
*1 (<3.25% Duty Factor).