XSR22FC-IKRIA1B1B1M2V0 controller operation password
时间:2026-03-23 阅读:124
What is the operation password for the flow totalizer XSR22FC-IKRIA1B1B1M2V0?
The operation password for the flow totalizer XSR22FC-IKRIA1B1B1M2VO is 01111 (four ones)
Guangzhou Wenlai flow totalizer XSR22FC-IKRIA1B1B1M2VO


1 Technical Specifications:
1. Input
Temperature display range: -999.9 to 999.9
Instantaneous flow rate and pressure display range: -99999 to 99999, with the decimal point position adjustable
Accumulated flow display range: 0~1000000000, decimal point position can be set
Input signal type:
Traffic: 1~5V DC, 0~5V DC, 4~20mA, 0~10mA, 0~20mA, 1~20000 Hz pulse
Temperature: No temperature, fixed temperature, Pt100, Cu100, Cu50 can be selected through settings
Pressure: No pressure, fixed pressure, 1~5V DC, 0~5V DC, 4~20mA, 0~10mA, 0~20mA
Other input signals or indexing numbers need to be specified when ordering
Flow totalizer XSR32FC-IKRIA1B1B1M2VO
Basic error: analog quantity less than ±0.2%F.S
Measurement resolution: 1/60000, 16-bit A/D converter
Measurement control cycle: 0.2 seconds per channel
Recording capacity: 4MBit
Recording interval: Settable from 1 second to 59 minutes and 59 seconds, with options for cyclic or non-cyclic recording
Record time: The length of record time is related to the recording interval, and the calculation formula is as follows:
Number of hours recorded = 12 × recording interval (in seconds)
3. Alarm
The alarm mode can be set to trigger based on instantaneous flow rate, temperature, or pressure limits, or the preset output mode can be configured for cumulative values
Relay output: contact capacity 220V AC, 3A
4. Transmitting function
4~20mA, 0~10mA, 0~20mA DC current output, selectable through settings. Load capacity greater than 500Ω
DC voltage output of 1~5V, 0~5V, 0~10V, please specify when ordering
Output resolution: 1/4000, with an error less than ±0.2% F.S
5. Communication interface
Optoelectronic isolation
RS232 and RS485 standards, please specify when ordering
The instrument address can be set from 0 to 99
Communication rates of 2400, 4800, 9600, and 19200 can be selected through settings. Rates lower than 2400 must be specified when ordering
The delay from the instrument receiving a command from the computer to sending a response with corresponding data is:
For commands with "#" as the delimiter, the response delay is less than 500μs; for other commands, the response delay is less than 100ms
Accompanying test software, providing configuration software and application software
6. External supply
Group 2, available in 24V or 12V options upon ordering: used to power the transmitter, with an output value error less than ±5% of the nominal value and a load capacity greater than 50mA
XSR32FC-IKRIA1B1B1VO flow controller
Instruments powered by 220V: Operating voltage range of 85V to 265V, with power consumption less than 8VA
24V DC, 12V DC, or other specifications, please specify when ordering
8. USB interface
The XSR22FC-IKRIA1B1B2V0 flow totalizer is compatible with USB flash drives that support USB 1.1 protocol