XSR22FC-IKRIA1B1B1M2V0 controller operation password

时间:2026-03-23      阅读:124

What is the operation password for the flow totalizer XSR22FC-IKRIA1B1B1M2V0?

The operation password for the flow totalizer XSR22FC-IKRIA1B1B1M2VO is 01111 (four ones)

Guangzhou Wenlai flow totalizer XSR22FC-IKRIA1B1B1M2VO

XSR22FC-IKRIA1B1B1M2V0 controller operation password

1 Technical Specifications:

1. Input

Temperature display range: -999.9 to 999.9

Instantaneous flow rate and pressure display range: -99999 to 99999, with the decimal point position adjustable

Accumulated flow display range: 0~1000000000, decimal point position can be set

Input signal type:

Traffic: 1~5V DC, 0~5V DC, 4~20mA, 0~10mA, 0~20mA, 1~20000 Hz pulse

Temperature: No temperature, fixed temperature, Pt100, Cu100, Cu50 can be selected through settings

Pressure: No pressure, fixed pressure, 1~5V DC, 0~5V DC, 4~20mA, 0~10mA, 0~20mA

Other input signals or indexing numbers need to be specified when ordering

Flow totalizer XSR32FC-IKRIA1B1B1M2VO

Basic error: analog quantity less than ±0.2%F.S

Measurement resolution: 1/60000, 16-bit A/D converter

Measurement control cycle: 0.2 seconds per channel

Recording capacity: 4MBit

Recording interval: Settable from 1 second to 59 minutes and 59 seconds, with options for cyclic or non-cyclic recording

Record time: The length of record time is related to the recording interval, and the calculation formula is as follows:

Number of hours recorded = 12 × recording interval (in seconds)

3. Alarm

The alarm mode can be set to trigger based on instantaneous flow rate, temperature, or pressure limits, or the preset output mode can be configured for cumulative values

Relay output: contact capacity 220V AC, 3A

4. Transmitting function

4~20mA, 0~10mA, 0~20mA DC current output, selectable through settings. Load capacity greater than 500Ω

DC voltage output of 1~5V, 0~5V, 0~10V, please specify when ordering

Output resolution: 1/4000, with an error less than ±0.2% F.S

5. Communication interface

Optoelectronic isolation

RS232 and RS485 standards, please specify when ordering

The instrument address can be set from 0 to 99

Communication rates of 2400, 4800, 9600, and 19200 can be selected through settings. Rates lower than 2400 must be specified when ordering

The delay from the instrument receiving a command from the computer to sending a response with corresponding data is:

For commands with "#" as the delimiter, the response delay is less than 500μs; for other commands, the response delay is less than 100ms

Accompanying test software, providing configuration software and application software

6. External supply

Group 2, available in 24V or 12V options upon ordering: used to power the transmitter, with an output value error less than ±5% of the nominal value and a load capacity greater than 50mA

XSR32FC-IKRIA1B1B1VO flow controller

Instruments powered by 220V: Operating voltage range of 85V to 265V, with power consumption less than 8VA

24V DC, 12V DC, or other specifications, please specify when ordering

8. USB interface

The XSR22FC-IKRIA1B1B2V0 flow totalizer is compatible with USB flash drives that support USB 1.1 protocol

 

 