常用淬火介质冷却特性检测对比

时间:2021-02-09      阅读:400

检测设备及标准

1.瑞典IVF冷却特性测试仪 Smartquench(SQ2)
2.采用ISO9950标准进行检测

样品介质及检测数据

编号样品名称浓度折光仪读数折光系数测试一测试二粘度(cSt)PH(8.5-1.05)
介质温度(℃)300℃gao冷速(℃/s)gao冷速所在温度(℃)介质温度(℃)300℃gao冷速(℃/s)gao冷速所在温度(℃)
冷速(℃/s)秒速(s)冷速(℃/s)秒速(s)
1-2好富顿AQ25162.332.583882.15.21526872985.64181713  
1-3好富顿AQ25183.132.563975.25.71456922975.24.4156701  
1-4好富顿AQ251103.92.563860.15.91517153063.75.1145701  
1-5好富顿AQ251124.652.583949.96.31467053051.15.4164722  
1-6好富顿AQ251166.32.543839.87.21487292841.26.4142732  
1-7好富顿AQ2512082.53829.79.11337092833.17.3133735  
2-2陶氏化学UCON-A2512.52386015.7855933073.56.9125702  
2-3陶氏化学UCON-A63.021.994091.66.114362632833.8194664  
2-4陶氏化学UCON-A84.031.994176.96.31246223278.84.5170705  
2-5陶氏化学UCON-A10524075.26.916068531724.3182707  
2-6陶氏化学UCON-A126.031.993865.15.91466992866.94.5171690  
2-7陶氏化学UCON-A16823957.36.51507082958.65.8155732  
2-8陶氏化学UCON-A2010.051.99385471337172853.86.3145721  

 

备注:
1.浓度采用质量百分比浓度,采用天平称重法配置;
2.折光仪采用糖量仪测试,读数读取的是溶液温度在25-28℃之间的读数值;
3.AQ251密度 15.6℃时为1.078g/cm3 UCON-A密度 20℃时为1.097g/cm3 ;
4.两者都是74℃逆溶析出 ;
5.UCON-A具有低的性能恶化和氧化速率(与一般PVA和溶性介质相比),故补充添加剂较少,主要补充因蒸发损失的水 。