西门子功率模块6SL3210-1PB13-0UL0
西门子功率模块6SL3210-1PB13-0UL0
西门子功率模块6SL3210-1PB13-0UL0
西门子功率模块6SL3210-1PB13-0UL0
西门子功率模块6SL3210-1PB13-0UL0

西门子功率模块6SL3210-1PB13-0UL0

参考价: 面议

具体成交价以合同协议为准
2021-09-26 11:08:19
406
产品属性
关闭
河南兆阳自动化科技有限公司

河南兆阳自动化科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

西门子功率模块6SL3210-1PB13-0UL0
河南兆阳公司在经营活动中精益求精,具备如下业务优势:
SIEMENS 可编程控制器1、SIMATIC S7 系列PLC:S7-200、S7-1500、S7-1200、S7-1500、S7-300、S7-400、ET-200逻辑控制模块 LOGO!230RC、230RCO、230RCL、24RC、24RCL等
2、SITOP直流电源 24V DC

详细介绍

西门子功率模块6SL3210-1PB13-0UL0

SINAMICS 功率模块 PM240-2 未过滤 带集成式制动斩波器 200-240V+10/-10% 1 AC/1/三相交流 47-63Hz 重过载功率:0.37kW 当 200% 3S,150% 57S, 100% 240S;环境温度 -10 至 +50°C,功率 轻过载:0.55kW 当 150% 3S, 110% 57S,100% 240S 环境温度 -10 至 +40°C 196x 73x 165(高x宽x深),FSA 防护等级 IP20 不带控制单元和 操作单元 批准从 CU 固件- 版本 4.6版起已获得许可

PM240‑2 Power Modules – 0.55 kW to 250 kW (0.75 hp to 400 hp), IP20 degree of protection

PM240‑2 Power Modules, frame sizes FSA to FSG (with Control Unit and Operator Panel)

The PM240‑2 Power Modules are based on a new hardware platform. This permits an increase in power density as well as the application of innovative cooling concepts (push-through technology) with especially high requirements in terms of control cabinet cooling.

Furthermore, the PM240-2 Power Module is also suitable for use in safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transformed into a Safety Integrated Drive (see section Control Units).

The PM240‑2 Power Modules in frame sizes FSA to FSF are available both with and without an integrated line filter class A of compact design for 200 V, 400 V and 690 V line voltages (except PM240‑2 frame sizes FSD to FSF: 200 V). The PM240‑2 Power Modules in frame size FSG are available with an integrated line filter Category C3 of compact design for 400 V and 690 V line voltages, also with integrated line filter Category C2 for a line voltage of 400 V. In addition, a DC link reactor is integrated in the PM240‑2 Power Modules, frame sizes FSD to FSG, and therefore no line reactor is required.

The PM240-2 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded Tn/TT systems and non-grounded IT systems.

The PM240‑2 Power Module has an integrated braking chopper. In generating mode, the excess energy of the DC link can be dissipated by means of an optional braking resistor.

河南兆阳自动化科技有限公司销售西门子千万余产品 尽新老顾客您来询价订货采购,欢迎您来兆阳公司,谢谢您的光临! 
连系人  :邵经理
电   :191+ 39 98+ 27 30        同微号

The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

Push-through variant

Example: PM240‑2 Power Modules, degree of protection IP20, push-through variant, frame sizes FSD to FSF (with Control Unit and Operator Panel)

The push-through variants in the frame sizes FSA to FSF allow the cooling fins of the Power Modules to be pushed through the rear panel of the control cabinet. Push-through variants should be used in applications where the amount of power loss generated inside the control cabinet itself must be minimized.

Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
For more information, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

PM250 Power Modules – 7.5 kW to 90 kW (10 hp to 125 hp), IP20 degree of protection

PM250 Power Modules, frame sizes FSC to FSF

PM250 Power Modules are suitable for a large number of applications in general mechanical engineering. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking chopper is not required).

The PM250 Power Module features an absolutely unique technology – Efficient Infeed Technology. This feature provides the ability to feed energy back into the supply system in the generator mode (electronic braking) so that the energy is not converted into heat in a braking resistor. This saves space in the control cabinet. The time-consuming process of dimensioning the braking resistor and the expense of the extra wiring are eliminated. Furthermore, heat losses in the control cabinet are reduced.

Further, the innovative circuit design reduces the line harmonics. There is no need to use an optional line reactor at the supply infeed. This saves space and costs for engineering and procurement.

The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

Frame sizes FSD to FSF of the PM250 Power Modules are available both with as well as without integrated line filter class A.

For frame size FSC of the PM250 Power Module with an integrated line filter class A, an additional base filter of class B is available for achieving class B (see section Line-side components).

The PM250 Power Module is also designed for safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transformed into a Safety Integrated Drive (see section Control Units).

The PM250 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded Tn/TT systems and non-grounded IT systems.

Note:

Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
For more information, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

西门子功率模块6SL3210-1PB13-0UL0

集成

All Power Modules have the following connections and interfaces:

Connection example for PM240‑2 Power Modules, frame sizes FSA to FSC, with or without integrated line filter

Connection example for PM240‑2 Power Modules, frame sizes FSD to FSG, with or without integrated line filter

Connection example for PM250 Power Modules with or without integrated line filter


上一篇:西门子S7-1200SM1231模拟量输入模块 下一篇:6ES7332-1SH71正确型号6EP1332-1SH71单价560
热线电话 在线询价
提示

请选择您要拨打的电话: