品牌
经销商厂商性质
郑州市所在地
西门子开关数字量电子模块6ES7132-4HB01
面议西门子模拟输入模块6ES7531-7PF00-0AB0
面议西门子V20变频器6SL3210-5BE31-5UV0
面议西门子S7 300CPU中央处理器6ES7315
面议西门子PM240功率模块6SL3210-1PE22-7UL0
面议西门子G120功率模块6SL3210-1PE26-0UL0
面议西门子通信处理器6GK7343-2AH11-0XA0
面议西门子ET 200ECO数字量模块6ES7144
面议西门子SD存储卡2GB 6AV2181-8XP00-0AX0
面议西门子S-1FL6伺服电机1FL6042-2AF21-1AB1
面议西门子6SL3210-5FB10-8UF0 V90变频器
面议西门子声光控制开关电感5UH8223-4NC01
面议西门子G120变频器6SL3244-0BB12-1BA1
SINAMICS G120 控制单元 CU240E-2 E-型配备安全集成 STO RS-485-接口,USS-协议 6DI,3DO,2AI,2AO,最大 1F-DI PTC/KTY 接口 USB 和 SD/MMC 接口 防护等级 IP20 环境温度 0 至 +50°C 无功率模块
概述CU230P‑2 Control Units
CU230P‑2 PN Control Unit
The Control Unit performs closed-loop control functions for the converter.
The CU230P-2 Control Units are designed for drives with integrated technological functions for pump, fan and compressor applications.
The I/O interface, the fieldbus interfaces and the additional software functions optimally support these applications. The integration of technological functions is a significant differentiating feature to the other Control Units of the SINAMICS G120 converter family.
The CU230P-2 Control Units can be operated with the following Power Modules:
河南兆阳自动化科技有限公司销售西门子千万余产品 尽新老顾客您来询价订货采购,欢迎您来兆阳公司,谢谢您的光临!
连系人 :邵经理
电 :191+ 39 98+ 27 30 同微号
PM240‑2
PM250
Note:
Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.
Typical, integrated HVAC/HLK functions
Linear and quadratic torque characteristic for fluid flow and positive displacement machines
ECO mode for additional energy saving in V/f control mode
2 analog inputs (current/voltage can be selected) to directly connect pressure/level sensors
2 additional analog inputs to connect Pt1000/LG‑Ni1000/DIN‑Ni1000 temperature sensors
Direct control of valves and flaps using two 230 V AC relays
Automatic restart
Flying restart
Skip frequencies
Hibernation mode
Load check function to monitor belts and flow
Cascade connection
4 integrated PID controllers (e.g. for temperature, pressure, air quality, level)
Multi-zone controller
Essential service mode
Real time clock with three time generators
IOP‑2 wizards for special applications
Pumps: Positive displacement (constant load torque) and centrifugal pumps (square load torque) with and without PID controller
Fans: Radial and axial fans (square load torque) with and without PID controller
Compressors: Positive displacement (constant load torque) and fluid flow machines (square load torque) with and without PID controller
Control Unit CU240E‑2
CU240E‑2 DP‑F Control Unit
The Control Unit performs closed-loop control functions for the converter.
The CU240E‑2 Control Unit is designed as standard Control Unit for all of the usual applications involving V/f or vector control.
CU240E-2 series with standard I/O quantity structure and integrated safety technology
The CU240E‑2 Control Unit can be combined with the following Power Modules:
PM240‑2
PM250
西门子G120变频器6SL3244-0BB12-1BA1
Note:
Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.
Safety Integrated Functions
The Safety Integrated Function "Safe Torque Off" (STO) (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3) is already integrated into the basic versions of the CU240E‑2 series (CU240E‑2, CU240E‑2 DP, CU240E‑2 PN).
With the fail-safe variants of the CU240E-2 series (CU240E‑2 F, CU240E‑2 DP-F, CU240E‑2 PN-F), the fail-safe SINAMICS G120 converter provides five safety functions which are certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3:
Safe Torque Off (STO)
to protect against active movement of the drive
Safe Stop 1 (SS1)
for continuous monitoring of a safe braking ramp
Safely-Limited Speed (SLS)
for protection against dangerous movements when a speed limit is exceeded (the CU240E‑2 DP Failsafe Control Unit has 4 selectable SLS limit values)
Safe Direction (SDI)
This function ensures that the drive can only rotate in the selected direction.
Safe Speed Monitor (SSM)
This function signals if a drive operates below a specific speed/feed velocity (CU240E‑2 DP‑F / CU240E‑2 PN‑F with PROFIsafe).
These functions can be activated by means of PROFIsafe or via the safety inputs.
None of the safety functions require a motor encoder and they are thus much cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SDI and SSM functions are only permissible for applications where the load can never accelerate when the converter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
Further information can be found in the section Safety Integrated.
CU250S‑2 Control Units
CU250S-2 Control Unit
The Control Unit performs closed-loop control functions for the converter.
The CU250S‑2 Control Units are designed as standard Control Units for all of the usual applications involving V/f or vector control.
CU250S‑2 Control Units can be used to implement all common applications involving V/f or vector control as well as applications for drives with positioning requirements. This expansion allows them to be used in lifting, swiveling, traversing or rotating applications. The positioning functionality is comparable with SINAMICS S110 servo drives.
Two points must be noted here:
Vector control (VC) and sensorless vector control (SLVC) are possible
Encoder possible for speed and position control (positioning)
The CU250S‑2 Control Units can be combined with the following Power Modules:
PM240‑2
PM250
Note:
Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.
Safety Integrated Functions
The following Safety Integrated Basic Functions (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3) are integrated as standard in the CU250S-2 series:
Safe Torque Off (STO)
to protect against active movement of the drive
Safe Stop 1 (SS1)
for continuous monitoring of a safe braking ramp
Safe Brake Control (SBC) is used to safely control a holding
brake
The following Safety Integrated Extended Functions (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3) are optionally available for the CU250S-2 series:
Safely-Limited Speed (SLS)
for protection against dangerous movements when a speed limit is exceeded
Safe Direction (SDI)
This function ensures that the drive can only rotate in the selected direction.
Safe Speed Monitor (SSM)
This function signals if a drive operates below a specific speed/feed velocity.
These functions can be activated by means of PROFIsafe or via the safety inputs.
None of the safety functions require a motor encoder and they are thus much cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SDI and SSM functions are only permissible for applications where the load can never accelerate when the converter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
Further information can be found in the section Safety Integrated.
设计CU230P‑2 HVAC, CU230P‑2 DP and CU230P‑2 PN Control Units