Bruel&Kjaer振动速度传感器上海壹侨贸易有限公司
:王昊强

-832

:
juanjuan.lang@onebridge.cn
地址:上海市嘉定区曹安公路2038号华拓大厦410室

详细介绍

Bruel&Kjaer振动速度传感器

Bruel&Kjaer振动速度传感器

TheBruel + Kjaer 4602Bephone Test Head allows accurate and repeatable positioning and subsequent measurement of a ephone handset in the standardized LRGP, HATS and AEN positions as recommended by the ITU-T, as well as in the REF position (OREM A). It is used as a general test jig with other Brüel & Kjær measurement equipment. The 4602B has been designed to accommodate handsets with antennas.

Bruel&Kjaer声级计产品型号:

上海壹侨贸易有限公司
:王昊强

-832
 
:
  juanjuan.lang@onebridge.cn
地址:上海市嘉定区曹安公路2038号华拓大厦410室
价注意事项:1.请提供*列的物料编号和第二列具体型号
       2.请发书面询价函(邮件,,传真等),不接受口头报价。
       3.如果型号不能*对上,请提供英文品牌名+具体型号+数量。
       4.询价的商友请主动告知公司名称和,谢谢。

:VS-068、VS-069、VS-077、VS-079、VS-080、VS-168、VS-169、VS-177、VS-277、VS-288、VS-289、电涡流轴位移传感器轴振动探头:SD-051、IN-081、IN-083、IN-084、IN-085、INA-081、INA-083、INA-085、DS-1051、DS-1052、DS-1053、DS-1054、SD-052、SD-053、SD-054、SD-081、SD-083、SD-084、SD-087、SD-088、SD-089、SDH-151、SDH-154、SD-161、SD-164、WT-010、WT-025
Bruel&Kjaer加速度计:AS-020、AS-022、AS-030、AS-060、AS-062、AS-065、AS-070、AS-080
Bruel&Kjaer电涡流轴位移传感器轴振动探头前置器:OD-051、OD-053、OD-054、OD-055、OD-081、OD-083、OD-061、OD-062、OD-151、OD-162、OD-165

Features and Benefits:

Artificial Ears and Ear Simulators
 

Ear Simulator Type 4157

Ear Simulator Type 4157 is primarily intended for frequency response, sensitivity and distortion measurements on earphones coupled to the ear by ear inserts such as tubes, ear moulds or eartips, for example, as used in hearing aids and operator headsets.

The Ear Simulator consists of a main housing into which are assembled a number of rings whose shapes form annular air volumes connected to the main volume of the housing by air passages. The main ear canal volume is of a similar shape and volume to that of the actual human ear and provides similar acoustic impedance to the insert earphone being tested.

Features

  • Conforms to IEC 711, ANSI S3.25, and ITU-T P.57 Type 2
  • Can be used to perform hearing aid testing to IEC 118-0 and IEC 118-7
  • Includes several insert-earphone adaptors
  • Built-in ½” Microphone Type 4134
  • Includes Preamplifier Type 2669, with individual calibration chart

Artificial Ears Types 4152 and 4153

Artificial Ears Types 4152 and 4153 have been designed for measurements in the audiometric and related fields. They enable electroacoustical measurements on either insert earphones or headphones to be carried out under well-defined acoustical conditions, which are of great importance for the comparability of different designs and the reproducibility of measurements.

The Artificial Ear consists of an acoustic coupler, a main housing containing the sockets for the connection of a Brüel & Kjær condenser microphone, and a baseplate with a mechanism for clamping the object being tested.

Features for 4152

  • Conforms to IEC126, ANSIS3.7 - 1973, and NBS9A
  • Used with 1” Microphone Type 4144 and Preamplifier Type 2669
  • 2 cm3 Coupler DB0138, 6cm3 Coupler DB0161, and 6cm3 Coupler DB0909 for measurements on insert type hearing aids, earphones and headphones

Features for 4153

  • Fulfils the requirements of IEC318
  • Uses a ½” microphone and preamplifier
  • 3-cavity coupler simulating the acoustic input impedance of a human ear
  • Test cap and flat plate adaptor included

Artificial Mastoid Type 4930

Artificial Mastoid Type 4930 has been designed for the calibration of bone conduction hearing aids and bone vibrators used in audiometry. It consists of a mechanical simulation of the human head, incorporating a built-in force transducer to monitor the output of the device to be calibrated. All the components of the Artificial Mastoid have been selected to ensure both excellent long-term stability and accurate correspondence with the mechanical characteristics of the human mastoid.

The Artificial Mastoid consists of an inertial mass, simulating the human head, mounted on a baseplate by resilient plastic spacers which surround the securing-bolts. The baseplate is carried on a suspension composed of three conical springs filled with foam rubber to provide damping. The natural frequencies of this suspension, which isolates the whole apparatus from external disturbances such as someone bumping the table during use, are all below 5 Hz, which is one-tenth of the low-frequency limit of the working range.

Features

  • Fulfils IEC373, BS4009, and ANSIS3.13 - 1972
  • Simulates mechanical impedance of human mastoid
  • Freq. range: 50Hz to 10kHz
  • Adjustable static force from 2 to 8N
  • Built-in force transducer to measure dynamic force and acceleration
  • Ear and Mouth Simulators for ephone Testing
     

    Brüel & Kjær's Test Head, Mouth Simulator and Ear Simulators provide optimal conditions for objective and standardised ephone testing. These products combine the requirements for acoustical performance with those for practical use. Ear and Mouth Simulators Types 4185, 4195 and 4227 are for use in ephone Test Head Type 4602B.

    Ear Simulator Type 4185

    Ear Simulator Type 4185 is designed for ephone measurements requiring an IEC318 coupler. This is suitable for measurements on high impedance earphones where sealed conditions are required.

    Features:

    • Conforms to IEC318 and ITU-T P.51 Type 1
    • Built-in sound source for seal checking
    • ½" microphone and preamplifier included
    • Individually calibrated (in accordance with ITU-T P.57)

    Wideband Ear Simulator Type 4195

    Wideband Ear Simulator Type 4195 has been designed to match the ear simulators in Head and Torso Simulator Type 4128C for measurements on ephone handsets. Type 4195 therefore provides a very realistic acoustical load to the ephone handset being tested and easily shows acoustic differences between ephone handsets as they appear in real use. This feature is vital when designing ephone handsets optimised for improved sound quality.

    Features:

    • Conforms to ITU-T P.51 Type 3.2
    • Provide realistic acoustic load (both high and low leak versions)
    • ½" microphone and preamplifier included
    • Individually calibrated (in accordance with ITU-T P.57)

    Mouth Simulator Type 4227

    Mouth Simulator Type 4227 is an accurate reference sound source developed for near field testing of ephone transmitters and microphones. It provides a standardised and realistic simulation of the human voice field.

    Features:

    • Conforms to IEEE-269, IEEE-661 and ITU-T P.51.
    • Accurate level and frequency response calibration is easily done using a Brüel & Kjær ½" microphone placed in the supplied calibration jig
    • Accurate simulation of human voice field
    • Quality control testing of frequency response and distortion of ephone transmitters and close-talking microphones
    • Continuous SPL of 100dB 25mm from lip ring
    • Low distortion
    • Built-in overload protection circuit