起订量:

| Output Ls | |
| Maximum Power per phase | 3000Ls: 1 phase 3000 VA, 3 phase 1000 VA; 4500Ls: 1 phase 4500 VA, 3 phase 1500 VA; 6000Ls: 1 phase 6000 VA, 3 phase: 2000 VA |
| Power factor | 0 to unity at full output VA |
| Voltage Ranges | |||
| Range | VLow | VHigh | |
| AC | 0 - 135 V | 0 - 270 V | |
| VA Programming Resolution | 100 mV |
| Load Regulation | < 0.1 % FS |
| Line Regulation | < 0.02 % for 10 % line change |
| See -HV and EHV options for alternative voltage range pairs. | |
| Programming Accuracy (25°C ±5°C) | Voltage (rms): ± (0.05% + 0.25) V from 5.0 V to FS; Frequency: ± 0.025%, 3 ø: <1° [45-100 Hz], <1° + 1°/kHz [>1kHz] |
| Frequency Range | 45 Hz - 1000 Hz (see -HF option for higher output frequencies) Programmable down to 17 Hz with lower V limit. |
| Frequency Resolution | 0.01 Hz at < 81.9 Hz, 0.1 Hz at >82.0 to 819.1 Hz, 1 Hz at > 819 Hz |
| Max RMS Current at Low V range | |
| At Full Power | |
| Model | 1 ø | 3 ø |
| 3000Ls | 44.4 A | 14.8 A |
| 4500Ls | 44.4 A | 14.8 A |
| 6000Ls | 44.4 A | 14.8 A |
| At Full Scale Voltage | ||
| Model | 1 ø | 3 ø |
| 3000Ls | 22.2 A | 7.4 A |
| 4500Ls | 33.3 A | 11.1 A |
| 6000Ls | 44.4 A | 14.8 A |
| Note: Constant power mode on 3000Ls and 4500Ls provides increased current at reduced voltage; | ||
| Current Limit | Programmable from 0 Amps to maximum current for selected range |
| Peak Current | 3000Ls: 6 X (lrms @ full scale voltage); 4500Ls: 4 X (lrms @ full scale voltage); 6000Ls: 3 X (lrms @ full scale voltage) |
| Output Noise | 100mV rms typ. (20 kHz to 1 MHz) - Standard 250mV rms typ. (20 kHz to 1 MHz) - Option -HF |
| Harmonic Distortion | < 1% (at full scale voltage, full resistive load) |
| Output Relay | Push button controlled and bus controlled output relay |
| Output Lx | |
| Maximum Power per phase | 3000Lx: 1 phase: 3000 VA, 3 phase: 1000 VA; |
| Power factor | 0 to unity at full output VA |
| Voltage Ranges | |||
| Range | VLow | VHigh | |
| AC | 0 - 150 V | 0 - 300 V | |
| VA Programming Resolution | 100 mV |
| Load Regulation | < 0.1 % FS ALC On or Reg. |
| Line Regulation | < 0.02 % for 10 % line change |
| See -HV and EHV options for alternative voltage range pairs. | |
| Programming Accuracy (25°C ±5°C) | Voltage (rms): ± (0.05% + 0.25) V from 5.0 V to FS, ALC On or Reg; Frequency: ± 0.025 %; Phase: ± 1° 45-100 Hz, ± (1° + 1°/kHz) 100 Hz-1kHz |
| Frequency Range | 45 Hz - 1000 Hz (see -HF option for higher output frequencies) (Derated voltage from 17 Hz - 45Hz) |
| Frequency Resolution | 0.01 Hz at < 81.9 Hz, |
| Max RMS Current at Low V range | |
| Phases V Range | VLow | VHigh |
| All 3 ø | 12.8 A | 6.4 A |
| models 1 ø | 38.4 A | 19.2 A |
| At Full Scale Voltage | ||
| Model | VLow | VHigh |
| 3000Lx 3 ø | 6.6 A | 3.3 A |
| 3000Lx 1 ø | 20.0 A | 10.0 A |
| 4500Lx 3 ø | 10.0 A | 5.0 A |
| 4500Lx 1 ø | 30.0 A | 15.0 A |
| 6000Lx 3 ø | 12.8 A | 6.4 A |
| 6000Lx 1 ø | 38.4 A | 19.2 A |
| Note: Constant power mode on 3000Lx and 4500Lx provides increased current at reduced voltage; 6000Lx provides maximum power output. | ||
| Current Limit | Programmable from 0 Amps to maximum current for selected range |
| Peak Current | 3000Lx: 5.7 X (lrms @ full scale voltage); 4500Lx: 3.8 X (lrms @ full scale voltage); 6000Lx: 3 X (lrms @ full scale voltage) |
| Output Noise | 100mV rms typ. 250mV rms typ. for -HF option |
| Harmonic Distortion | < 1% (at full scale voltage, full resistive load) |
| Output Relay | Push button controlled and bus controlled output relay |
| Input Ls | |
| Voltage | Models 3000Ls, 4500Ls, 9000Ls, 13500Ls: Standard: 208-230 ± 10% VAC, (L-L, 3 Phase); Option -400: 400 ± 10% VAC (L-L, 3 Phase) Includes CE Mark; Models 6000Ls, 12000Ls, 18000Ls: Standard 208-230 + 10% VAC (L-L, 3 Phase) Notes: 1. Input must be specified when ordering. 2. -400 option not availble on 6000Ls, 12000Ls, 18000Ls. 3. 3000Ls can be operated from 1 phase AC. 4. -480V option ± 5% VAC (L-L, 3 Phase) available on 3000Ls & 4500 Ls (3 phase output only) |
| Line Current (rms per phase) | |
| Model | 187 VLL | 187 VLN (1 ø) | 208 VLL | 360 VLL |
| 3000Ls | 19 A | 32 A | n/a | 10 A |
| 4500Ls | 31 A | n/a | n/a | 16 A |
| 6000Ls | n/a | n/a | 38 A | n/a |
| Inrush Current (Per phase) | @ 180-254 V: 50 A peak @ 360-440 V: 83 A peak |
| Line Frequency | 47-440 Hz |
| Efficiency | 80% typical |
| Power Factor | 0.7 typical |
| Hold-up Time | At least 10 ms |
| Input Lx | |
| Voltage | ModeLx 3000Lx, 4500Lx, 9000Lx, 13500Lx: Standard: 208-230 ± 10% VAC, (L-L, 3 Phase); Option -400: 400 ± 10% VAC (L-L, 3 Phase) Includes CE Mark; ModeLx 6000Lx, 12000Lx, 18000Lx: Standard 208-230 + 10% VAC (L-L, 3 Phase) Notes: 1. Input must be specified when ordering. 2. -400 option not availble on 6000Lx, 12000Lx, 18000Lx. 3. 3000Lx can be operated from 1 phase AC. |
| Line Current (rms per phase) | |
| Model | 3000Lx | 3000Lx (1Phase) | 4500Lx | 6000Lx (@ 280V) |
| 187 VLL | 19 A | 32 A | 31 A | 38 A |
| 360 VLL | 10 A | n/a | 16 A | n/a |
| Inrush Current (Per phase) | @ 180-254 V: 50 A peak @ 360-440 V: 83 A peak |
| Line Frequency | 47-440 Hz |
| Efficiency | 80% typical |
| Power Factor | 0.7 typical |
| Hold-up Time | At least 10 ms |
| Ls Measurements - Standard (AC Measurements) | ||||
| Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
| Range | 45-1000Hz | 45-100Hz 100-1000Hz | 0-400V | 0-50A |
| Accuracy* (±) 1 ø mode (-1) | 0.1% + 1 digit | 0.5° 2° | 0.05% + 250 mV | 0.1% + 150 mA |
| Accuracy* (±) 3 ø mode (-3) | 0.1% + 1 digit | 0.5° 2° | 0.05% + 250 mV | 0.1% + 50 mA |
| Resolution* | 0.01 Hz / 0.1 Hz / 1 Hz | 0.1° | 10 mV | 1 mA |
| Parameter | Real Power | Apparent Power | Power Factor |
| Range | 0-6kW | 0-6kVA | 0.00-1.00 |
| Accuracy* (±) 1 ø mode (-1) | 0.15% + 9 W | 0.15% + 9 VA | 0.03 |
| Accuracy* (±) 3 ø mode (-3) | 0.15% + 3 W | 0.15% + 3 VA | 0.01 |
| Resolution* | 1 W | 1 VA | 0.01 |
| * Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are multiplied by 3. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms. | |||
| Lx Measurements - Standard (AC Measurements) | ||||
| Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
| Range | 45.00-81.91 Hz 82.0-819.1 Hz > 819 Hz | 0.0° - 359.9° | 0-400V | 0-50A |
| Accuracy* (±) 1 ø mode (-1) | 0.1% + 1 digit | 0.5° < 100 Hz 2° > 100 Hz | 0.05% + 0.25V | 0.1% + 0.15A |
| Accuracy* (±) 3 ø mode (-3) | 0.1% + 1 digit | 0.5° < 100 Hz 2° > 100 Hz | 0.05% + 0.25V | 0.1% + 0.05A |
| Resolution* | 0.01 Hz / 0.1 Hz / 1 Hz | 0.1° / 1° | 10 mV | 1 mA |
| Parameter | Crest Factor | Real Power | Apparent Power | Power Factor |
| Range | 1.00 - 10.0 | 0-6kW | 0-6kVA | 0.00-1.00 |
| Accuracy* (±) 1 ø mode (-1) | 1.5% | 0.15% + 9 W | 0.15% + 9 VA | 0.03 |
| Accuracy* (±) 3 ø mode (-3) | 1.5% | 0.15% + 3 W | 0.15% + 3 VA | 0.01 |
| Resolution* | 0.01 | 1 W | 1 VA | 0.01 |
| * Accuracy specifications are in % of reading + scale error and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. CF accuracy applies for Irms > 50 % of max. PF accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 20 Vrms. | ||||
| Ls System | |
| Storage | Setup: 16 complete instrument setups / Transient List: 100 transient steps per list (SCPI mode) or 16 transient registers (APE mode) |
| Trigger Input/Output | Input: Triggers measurements or transient steps - SMA connector: 10K pull-up / Output: SMA Connector: HCTTL output |
| Lx System | |
| Storage | Setup: 16 complete instrument setups / Transient List: 100 transient steps per list (SCPI mode) |
| Trigger Input/Output | Input: Triggers measurements or transient steps - SMA connector: 10K pull-up / Output: SMA Connector: HCTTL output |
| Ls Protection | |
| Overload/Temp/Voltage | Overload: Constant current or constant voltage mode; Over temperature: Automatic Shutdown; Over voltage: Automatic shutdown |
| Lx Protection | |
| Overload/Temp/Voltage | Overload: Constant current or constant voltage mode; Over temperature: Automatic Shutdown; Over voltage: Automatic shutdown |
| Regulatory/RFI Suppresion | IEC1010, EN50081-2, EN50082-2, CE (for 400V input only), EMC, and safety mark requirements / RIF Suppression: CISPR 11, Group1, Class A |
| Ls Remote Control | |
| IEEE-488 Interface | IEEE-488 (GPIB) talker listener. Subset: AH1, DC1, DT1, L3, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
| USB Interface & Ethernet (option) | Version: USB 1.1; Speed: 460 Kb/s maximum / Ethernet Interface (Optional): specify -LAN option. 10BaseT, 100BaseT, RJ45 |
| RS232C Interface | Bi-directional serial interface; 9-pin D-shell connector. Handshake: CTS, RTS. Databits: 7 w/ parity, 8 w/o parity. Stopbits: 2. Baud rate: 9600 to 115200. Supplied with RS232C cable / Code and Format: SCPI; APE and Able : option -GPIB |
| Lx Remote Control | |
| IEEE-488 Interface | IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
| USB Interface & Ethernet (option) | IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
| RS232C Interface | Bi-directional serial interface; 9-pin D-shell connector. Handshake: CTS, RTS. Databits: 7 w/ parity, 8 w/o parity. Stopbits: 2. Baud rate: 9600 to 115200. Supplied with RS232C cable / Code and Format: SCPI / Not enabled if LAN option is present. |
| Ls Physical Dimensions | |
| Dimensions (per chassis) | Height: 10.5” (267 mm), Width: 19” (483 mm), Depth: 23.7” (602 mm) (depth includes rear panel connectors) |
| Weight | Chassis: Net: 193 lbs / 87.7 Kg, Shipping: 280 lbs / 127.3 Kg (for /2 or /3 model configuarations multiply by number of chassis). |
| Vibration and Shock | Designed to meet NSTA project 1A transportation levels |
| Air Intake/Exhaust | Forced air cooling, side air intake, rear exhaust |
| Temperature | Temperature: Operating: 0 to 35° C, full power / Storage: -40 to +85° C; |
| Diagnostics | Built-in self test available over bus (*TST) |
| Rear Panel Connectors | * Three phase AC input and output terminal block with safety cover. * IEEE-488 (GPIB) connector (Option -GPIB). * 9-pin D-Shell RS232C connector (RS232 DB9 to DB9 cable supplied). * Remote Inhibit (INH) and Discrete Fault Indicator (DFI). * Remote voltage sense terminal block. * Trigger In1 and Trigger Out1. * System interface connectors. * Auxilary Output (Option -AX) |
| Lx Physical Dimensions | |
| Dimensions (per chassis) | Height: 10.5” (267 mm), Width: 19” (483 mm), Depth: 23.7” (602 mm) (depth includes rear panel connectors) |
| Weight | Chassis: Net: 193 lbs / 87.7 Kg, Shipping: 280 lbs / 127.3 Kg (for /2 or /3 model configuarations multiply number of chassis) |
| Vibration and Shock | Designed to meet NSTA project 1A transportation leveLx |
| Air Intake/Exhaust | Forced air cooling, side air intake, rear exhaust |
| Temperature | Temperature: Operating: 0 to 35° C, full power / Storage: -40 to +85° C; |
| Diagnostics | Built-in self test available over bus (*TST) |
| Rear Panel Connectors | * Three phase AC input and output terminal block with safety cover. * IEEE-488 (GPIB) connector, USB connector, RJ45 connector (with -LAN Option). * 9-pin D-Shell RS232C connector (RS232 DB9 to DB9 cable supplied). * Remote Inhibit (INH) and Discrete Fault Indicator (DFI). * Remote voltage sense terminal block. * Trigger In1 and Trigger Out1. * System interface connectors. * Auxilary Output (Option -AX) |
| Ls Option -ADV Specifications | |||
| Measurements | |||
| Parameter | Frequency Fundamental Harmonics | Voltage | Current |
| Range | 45-81.91 Hz / 45.00 Hz-16 kHZ | 0 - 400 V | 0 - 20 Amps |
| Accuracy* (±) | 0.1% ± 1 digit / 0.1% + 2 digit | 0.05% + 0.25V / 0.1% + 0.1%/kHZ + 0.25 | 0.1% + 0.05A / 0.1% + 0.1%/kHz +0.05A |
| Resolution | 01 Hz / 0.1 Hz. | .01 V / .01V | .01 A / .01 A |
| * Accuracy specifications are in a percent of reading for single unit in 3-phase mode. | |
| Waveforms | Pre-defined: Sine, Square, Clipped, User-defined, 1024 addressable data points; Storage: 50 user waveforms, non-volatile memory |
| Data Acquisition | Parameters: Voltage, Current time domain, per phase; Resolution: 4096 data points, 10.4 usec (1ø) or 31.25 usec (3ø) sampling interval |
| Lx Ls -ADV Specifications | |||
| Measurements | |||
| Parameter | Frequency Fundamental Harmonics | Voltage | Current |
| Range | 45-1000 Hz / 45 - 16 kHz | Harmonics 2 - 50 | Harmonics 2 - 50 |
| Accuracy* (±) | 0.1% + 1 digit / 0.1% + 2 digits | 0.1% + 0.1% /1 kHz +0.25V | 0.1% + 0.1% /1 kHz +0.05A |
| Resolution | 0.01 Hz / 0.1 Hz | 10 mV | 10 mA |
| * Accuracy specifications are in a percent of reading for single unit in 3-phase mode. | |
| Waveforms | Pre defined: Sine, Square, Clipped; User defined: 1024 addressable data points; Storage: 50 user waveforms, non-volatile memory |
| Data Acquisition | Parameters: Voltage & Current time domain, per phase; Resolution: 4096 data points, 10.4 usec (1ø) or 31.25 usec (3ø) sampling interval |
| Ls Option -AX Specifications | |
| Option -AX | Provides seperate isolated 26 VAC regulated and 5 Vac unregulated outputs. The 26 V is normally used for servo-synchro excitation, and the 5 V for lamp power. 26 Volt-Accuracy: ± 2%. Current capacity: 3 ARMS. Frequency: 360/440 Hz. Regulation ± 1.5%. 5 Volt-Accuracy: ± 5%. Current capacity: 1 ARMS |
| Lx Option -AX Specifications | |
| Option -AX | Provides seperate isolated 26 VAC regulated and 5 Vac unregulated outputs. The 26 V is normally used for servo-synchro excitation, and the 5 V for lamp power. 26 Volt-Accuracy: ± 2%. Current capacity: 3 ARMS. Frequency: 360/440 Hz. Regulation ± 0.05%. 5 Volt-Accuracy: ± 5%. Current capacity: 5 ARMS |
| Ls Standard -EHV Specifications | |
| Voltage / Frequency Ranges | Voltage: Low: 0-200 Volt; High: 0-400 Volt / Frequency: With -HF option: 45 Hz - 5000 Hz |
| Max RMS Current at Full Power | 3 Phase: High: 5.0 A, Low 10.0 A; 1 Phase: High: 15.0A, Low: 30.0 A; Note: Constant power modes on 3000Ls and 4500Ls. Current available at reduced voltage for 3000Ls, 4500Ls, and max voltage for 6000Ls |
| Max RMS Current at FSVoltage | 3000Ls: 3 Phase: High: 2.5 A, Low: 5.0 A; 1 Phase: High 7.5 A, Low: 15.0 A; 4500Ls: 3 Phase: High: 3.8, Low 7.5; 1 Phase: High: 11.3 A, Low: 22.5 A; 6000Ls: 3 Phase: High: 5.0 A, Low 10.0 A; 1 Phase: High: 15.0 A, Low: 30.0 A |
| Lx Standard -EHV Specifications | |
| Voltage / Frequency Ranges | Low Range: 0-135 Volt; High Range: 0-270 Volt RMS: With -HF option: 45 Hz - 5000 Hz |
| Max RMS Current at Full Power | 3 Phase: High: 7.4 A, Low 14.8 A; 1 Phase: High: 22.2 A, Low: 44.4 A; Note: Constant power modes on 3000Lx and 4500Lx. Current available at reduced voltage for 3000Lx, 4500Lx, and max voltage for 6000Lx |
| Max RMS Current at FSVoltage | 3000Lx: 3 Phase: High: 3.7 A, Low: 7.4 A; 1 Phase: High 11.1 A, Low: 22.2 A; 4500Lx: 3 Phase: High: 5.6, Low 11.1; 1 Phase: High: 16.7 A, Low: 33.3 A; 6000Lx: 3 Phase: High: 7.4 A, Low 14.8 A; 1 Phase: High: 22.2 A, Low: 44.4 A |
| Ls Option -HV Specifications | ||||
| Measurements: F < 2000 Hz: See standard Ls Specifications; F > 2000 Hz: See table > | ||||
| Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
| Range | <2000 Hz >2000 Hz | 0-400 V< 1000 Hz / > 1000 Hz | 0-50 A | |
| Accuracy* (±) 1 ø mode (-1) | 0.1% ± 1 digit | 0.5° 2° 5° | 0.05% + 250 mV | 0.5% + 150 mA |
| Accuracy* (±) 3 ø mode (-3) | 0.1% ± 1 digit | 0.5° 2° 5° | 0.1 % + 0.1%/kHz + 300MV | 0.5% + 50 mA |
| Resolution* | 0.01 Hz / 0.1 Hz / 1 Hz | 0.1° | 10 mV | 1 mA |
| Parameter | Real Power | Apparent Power | Power Factor |
| Range | 0-6 kW | 0-6 kVA | 0.00-1.00 |
| Accuracy* (±) 1 ø mode (-1) | 0.5% + 9W | 0.5% + 9 VA | 0.03 |
| Accuracy* (±) 3 ø mode (-3) | 0.5% + 3W | 0.5% + 3 VA | 0.01 |
| Resolution* | 1 W | 1 VA | 0.01 |
| * Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are multiplied by 3. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms. | |||
| Frequency Range | 45 Hz- 5000 Hz |
| Output Noise | <250 mVrms typical (20 kHz to 1 MHz) |
| Lx Option -HV Specifications | ||||
| Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
| Range | 45.00 - 5000 Hz | 0.0°-359.9° | 0-400 V < 1000 Hz / > 1000 Hz | 0-50 A |
| Accuracy* (±) 1 ø mode (-1) | 0.1% + 1 digit | 0.5° < 100Hz 2° < 2Khz 5° > 2Khz | 0.05% + 0.25V / 0.1 % + 0.1%/kHz + 0.3V | 0.5% + 0.15A |
| Accuracy* (±) 3 ø mode (-3) | 0.1% + 1 digit | 0.5° < 100Hz 2° < 2Khz 5° > 2Khz | 0.05% + 0.25V / 0.1 % + 0.1%/kHz + 0.3V | 0.5% + 0.05A |
| Resolution* | 0.01 Hz / 0.1 Hz / 1 Hz | 0.1° | 10 mV | 1 mA |
| Parameter | Crest Factor | Real Power | Apparent Power | Power Factor |
| Range | 1.00 - 10.0 | 0-6 kW | 0-6kVA | 0.00-1.00 |
| Accuracy* (±) 1 ø mode (-1) | 1.5% | 0.5% + 9 W | 0.5% + 9 VA | 0.03 |
| Accuracy* (±) 3 ø mode (-3) | 1.5% | 0.5% + 3 W | 0.5% + 3 VA | 0.01 |
| Resolution* | 0.01 | 1 W | 1 VA | 0.01 |
| * Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. CF accuracy applies for Irms > 50 % of max. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 20 Vrms. | ||||
| Frequency Range | 45 Hz- 5000 Hz (Derated voltage from 17 Hz - 45Hz) |
| Frequency Accuracy | ±0.025% |
| Output Noise | 250 mVrms typical (20 kHz to 1 MHz) |
| 附带 |
| 光盘上的用户/编程手册、软件和 RS232C 串行电缆。 |
| 输出选件 | |
| -AX¹ | 辅助输出,26 VAC,5 VAC。将上限频率限制为 800 Hz。 |
| -HV¹ | 156/312 V 输出范围。 |
| -EHV¹ | 200/400 V 输出范围。 |
| -HF¹ | 扩展频率上限。见 HF 表。 |
| -LF¹ | 将输出频率限制为 500 Hz。 |
| -FC | 将输出频率控制更改为 ±0.25% |
| 控制器选件 | |
| 选件代码 | 描述 |
| -ADV | 高级功能集。增加了任意波形生成和电压、电流的谐波分析。 |
| -EXS | 外部同步。 |
| -GPIB | GPIB 接口和 APE 编程语言。 |
| -LAN | 以太网接口。 |
| -MB | 多箱。将控制器添加到多机箱系统的辅助机箱。 |
| -MODE | 为 3 个型号添加相位模式选择。 |
-L22 | 锁定旋钮 |
| -LKM¹ | 时钟和锁定主设备 |
| -LKS¹,² | 时钟和锁定辅助设备 |
| -LNS² | 线路同步 |
| -EXS² | 外部同步。 |
| LS 航空电子设备测试常规选件 | |
| 选件代码 | 描述 |
| -ABD | 空客指令 0100.1.8 测试。[ AC]。需要 -ADV 和使用 Windows PC 及附带的 FCS 系列 II 仪器控制软件。 |
| -AMD | 空客 AMD24C 测试。C 版。 |
| -A350 | 空客测试软件 |
| -AIRB | 空客 ABD0100.1.8、AMD 24 和 A350 组合测试软件套件 |
| -704 | 标准 704 版 D 和 E 测试固件。[ AC,详情请参阅 -704 选件数据表] |
| -704F | 标准 704 测试固件。A-F 版。 |
| -160 | RTCA/DO-160D、Change 2、EuroCAE-14D 和空客测试固件 [第 16 节, AC。详情请参阅 -160 选件数据表] |
| *注意 有关性能功能的完整列表,请参阅航空电子设备测试用户手册 P/N 4994-971。 | |
| LX 航空电子设备测试常规选件 | |
| 选件代码 | 描述 |
| -ABD | 空客指令 0100.1.8 测试。[ AC]。需要 -ADV 和使用 Windows PC 及附带的 FCS 系列 II 仪器控制软件。 |
| -AMD | 空客 AMD24C 测试。C 版。 |
| -A350 | 空客测试软件 |
| -AIRB | 空客 ABD0100.1.8、AMD 24 和 A350 组合测试软件套件 |
| -B787 | 波音 787 测试软件 |
| -704 | 标准 704 版 D 和 E 测试固件。[ AC,详情请参阅 -704 选件数据表] |
| -704F | 标准 704 测试固件。A-F 版。 |
| -160 | RTCA/DO-160D、Change 2、EuroCAE-14D 和空客测试固件 [第 16 节, AC。详情请参阅 -160 选件数据表] |
| *注意 有关性能功能的完整列表,请参阅航空电子设备测试用户手册 P/N 4994-971。 | |
| 机柜选件 | |
| C 前缀 | 机柜系统。已在 19 英寸机柜中安装和预接线。 |
| 标准 -EHV 规格 | ||||
| HF | LF | HV | EHV | |
| HF | - | X | O | O |
| LF | X | - | O | O |
| HV | O | O | - | X |
| EHV | O | O | X | - |
| LKM | X | O | O | O |
| LKS | X | O | O | O |
| EXS | O | O | O | O |
| AX | X | O | O | O |
| LKM | LKS | EXS | AX | |
| HF | X | X | O | X |
| LF | O | O | O | O |
| HV | O | O | O | O |
| EHV | O | O | O | O |
| LKM | - | O | O | O |
| LKS | X | - | X | O |
| EXS | O | X | - | O |
| AX | O | O | O | - |