新!现在提供 ProfiNET 数字接口!
规格
| 类型 | BCG450 | |
|---|---|---|
| 测量范围 | 5×10-10 … 1500 | |
| 精度 | ||
| 10-8 … 50 毫巴 | % of reading | ±15 |
| 50 … 950 毫巴 | % of reading | ±5 |
| 950 … 1050 毫巴 | % of reading | ±2.5 |
| 可重复性 | ||
| 10-8 … 10-2 毫巴 | % of reading | 5 |
| 热离子发射 | mbar | 2×10-2 (high) |
| (可选高/低,通过 RS232 / 现场总线) | mbar | 8×10-3 (low) |
| 除气 (1) | ||
| p < 7.2="" ×="">-6 | mbar | electron bombardment, max. 3 min |
| 压力, | bar (absolute) | 5 |
| 温度 | ||
| 运行(环境) | °C | 0 … +50 |
| 贮存 | °C | -20 … +70 |
| 在法兰处烘烤 | °C | 80 |
| 移除烘烤电子设备 | °C | 150 |
| 电源电压 | 20 … 28 | |
| 输出信号模拟 | ||
| 输出信号 | V | 0 … 10.3 |
| 测量范围输出 | V | 0.774 … 10.3 |
| 电压与压强之间的关系 | volts per decade | 0.75 |
| 错误信号 | V | 0.3 / 0.5 |
| 最小负载 | kΩ | 10 |
| 接口(数字)(2) | RS232C | |
| 连接器 | D-Sub, 15-pin, male | |
| 电缆长度, (3) | m (ft.) | 100 (330) |
| 暴露于真空的材料 | Yt2O3, Ir, Mo, Cu, W, NiFe, NiCr, AI2O3, SnAg, stainless steel, glass | |
| 内部容积 KF / CF | cm³ (in.³) | 24 (1.46) / 34 (2.1) |
| 重量 KF / CF | g | 285 / 550 |
| 保护等级 | IP30 | |
| DeviceNet™ | ||
| 协议 | DeviceNet™, group 2 slave only | |
| 数据率开关 | kBaud | 125, 250, 500 or network programmable |
| 电缆长度 125 kbps | m (ft.) | 500 (1650) |
| 电缆长度 250 kbps | m (ft.) | 250 (825) |
| 电缆长度 500 kbps | m (ft.) | 100 (330) |
| MAC ID | 2 switches (address 00 - 63) or network programmable | |
| 网络规模 | up to 64 nodes per segment | |
| 数字功能 | read pressure, select units: Torr, mbar, Pa; degas function, monitor gauge status, safe state allows definition of behavior in case of error, detailed alarm and warning information | |
| 模拟功能 | 0 … 10 V analog output pressure indication, two setpoint relays A + B | |
| 可视通信指示器 | LED network status (green / red) ; LED module status (green / red) | |
| 技术规格 | DeviceNet™ "Vacuum Gauge Device Profile" | |
| 设备类型 | ''CG'' for combination gauge | |
| I / O 从属传讯 | polling only | |
| 设定点继电器: 设定点数量 | 2 | |
| 设定点继电器: 范围 | mbar | 1×10-9 … 1400 |
| 设定点继电器: 继电器触点 | n.o., potential free | |
| 设定点继电器: 滞后 | % of reading | 10 |
| 设定点继电器: 触点额定值 | 60 | |
| 设定点继电器: 连接器 | D-Sub, 15-pin, male | |
| DeviceNet™ 电源电压 | 11 … 25 | |
| 真空计电源电压 | 20 … 28 | |
| DeviceNet™ 连接器 | Microstyle, 5-pin | |
| BCG(模拟输出、电源电压、设定点)连接器 | D-Sub, 15-pin, male | |
| Profibus DP | ||
| 波特率 | 9.6 / 19.2 / 93.75 / 187.5 / 500 | |
| 地址 | 2 switches (address 00 - 127) or network programmable | |
| 数字功能 | read pressure, select units: Torr, mbar, Pa; degas function, monitor gauge status, safe state allows definition of behavior in case of error, detailed alarm and warning information | |
| 模拟功能 | 0 … 10 V analog output pressure indication, two setpoint relays A + B | |
| 设定点继电器: 设定点数量 | 2 | |
| 设定点继电器: 范围 | mbar | 1×10-9 … 1400 |
| 设定点继电器: 继电器触点 | n.o., potential free | |
| 设定点继电器: 滞后 | % of reading | 10 |
| 设定点继电器: 触点额定值 | 60 | |
| Profibus DP 连接器 | D-Sub, 9-pin, female | |
| BCG(模拟输出、电源电压、设定点)连接器 | D-Sub, 15-pin, male | |
| 以太网 | ||
| 以太网协议 | protocol specialized for EtherCAT | |
| 通讯标准 | ETG.5003.1 S (R) V1.1.0: Part 1 Common Device Profile (CDP)ETG.5003.2080 S (R) V1.3.0: Part 2080: Specific Device Profile (SDP) Vacuum Pressure Gauge | |
| 节点地址 | Explicit Device Identification | |
| 物理层 | 100BASE-Tx (IEEE 802.3) | |
| 以太网数字功能 | read pressure, select units: Torr, mbar, Pa emission control, degas function monitor gauge status, filament status safe state allows definition of behavior in case of error detailed alarm and warning information | |
| 过程数据 | Fixed PDO mapping and configurable PDO mapping | |
| 邮箱 (CoE) | SDO requests, responses and information | |
| 以太网连接件 | RJ45, 8-pin (socket), IN and OUT | |
| 电缆 | shielded Ethernet CAT5e or higher | |
| 电缆长度 | m (ft.) | ≤100 (330) |
| Profinet | ||
| Communication protocol | protocol specalized for Profinet | |
| Data rate | 100 Mbps | |
| Physical layer | 100BASE-Tx (IEEE 802.3) | |
| Digital functions Profinet | read pressure, select Units (Torr, mbar, Pa), emisson control, degas function, monitor gauge status, filament status | |
| Analog function | 10 … 10 V anlog output pressure indication | |
| Profinet connector | 2 x RJ45, 8-pin (socket), input & output | |
| Profinet Cable | Special Ethernet Patch Cable or Crossover Cable, shielded (CAT5e quality or higher) | |
| Cable lenght | <100 m (330 ft) | |
| Cyclic data | IO-data | |
| Mailbox (CoE) Profinet | configuration, responses and information | |
1)除气期间准确性降低
2)不可同时使用 RS232C 或 VGC40x 系列控制器和现场总线
3)RS232C 操作 <>
零件号
| BCG450 | |
|---|---|
| 零件号 | 明细 |
| 353-550 | BCG450 规管 |
| 353-551 | BCG450 TripleGauge; DN 40 CF-R |
| 353-552 | BCG450 规管 |
| 353-553 | BCG450 TripleGauge; DN 40 CF-R |
| 353-554 | BCG450-SP TripleGauge; DN 25 ISO-KF |
| 353-556 | BCG450-SP TripleGauge; DN 40 CF-R |
| 353-557 | BCG450-SD TripleGauge; DN 25 ISO-KF |
| 353-558 | BCG450-SD TripleGauge; DN 40 CF-R. |
| 353-592 | BCG450-SE ECAT, DN 25 ISO-KF |
| 353-593 | BCG450-SE ECAT, DN 40 CF-R |
| 353-598 | BCG450-SE ECAT, DN 25 ISO-KF |
| 353-599 | BCG450-SE ECAT, DN 40 CF-R |
| 353-517 | BCG450-PN Profinet, DN 25 ISO-KF |
| 353-518 | BCG450-PN Profinet, DN 40 CF-R |
| 354-492 | BCG450 传感器 |
| 354-493 | BCG450 Spare measurement systemDN40CF-R. |
| 353-606 | BCG450 TripleGauge; W, DN 40 CF-R |
附件
| BCG450 | |
|---|---|
| 零件号 | 明细 |
| 353-511 | BPG400 24V电源 |
| 353-512 | Baffle for BPG400 |
| 211-113 | 中心圈 with baffle DN 25 KF |
备件
| BCG450 | |
|---|---|
| 零件号 | 明细 |
| 354-492 | BCG450 传感器 |
| 354-493 | BCG450 Spare measurement systemDN40CF-R. |
数据表
手册
手册
三维步骤文件
其他文件